Theory Flow Sensors

Flow sensors measure the flow rate of a gas or liquid. This makes them indispensable in many technological applications. There are different methods to measure the flow.

30 Products found

PFLOWC5001

Measuring range [SCCM]
0 to 0.05...20 SLPM
Output signal
Linear, 0.5...4.5 VDC, RS232, Rs485 Modbus
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW5001

Measuring range [SCCM]
0 to 0.1...20 SLPM or 0 to ±0.1...±20 SLPM
Output signal
Linear, 0.5...4.5 VDC, Rs485 Modbus, I2C
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW5002 / PFLOWC5002

Measuring range [SCCM]
0 to 0.05...20 SLPM
Output signal
Linear, 0.5...4.5 VDC, RS232, Rs485 Modbus
Accuracy [± % FS] max.
±1 r.d. or ±0.2 f.s whichever is larger
Supply voltage [VDC]
8...24

PFLOW3008

Measuring range [SCCM]
0 to 2...50 SLPM
Output signal
Linear, 0.5...4.5 VDC, Rs485 Modbus, I2C
Accuracy [± % FS] max.
±(1.5+0.2FS)
Supply voltage [VDC]
8...24

PFLOW4008

Measuring range [SCCM]
0 to 2...50 SLPM
Output signal
Linear, 0.5...4.5 VDC, IO-Link, I2C
Accuracy [± % FS] max.
1.5
Supply voltage [VDC]
8...24

PFLOW2001

Measuring range [SCCM]
0 to 10...5000 SCCM
Output signal
Linear, 0.5...4.5 VDC, I2C
Accuracy [± % FS] max.
1.5
Supply voltage [VDC]
2.7...15
New

PFLOW9015CL

Measuring range [SCCM]
0..100 SLPM
Output signal
I2C
Accuracy [± % FS] max.
±2%
Supply voltage [VDC]
5V ±5%

PFLOW-CUSTOM-MADE

Measuring range [SCCM]
Customized
Output signal
Customized
Accuracy [± % FS] max.
Customized
Supply voltage [VDC]
Customized

V3D air velocity sensor

Measuring range [SCCM]
0 to 30...4000 SCCM
Output signal
Linear, 0.5...4.5 VDC
Accuracy [± % FS] max.
5
Supply voltage [VDC]
2.75...5.5
New

PFLOW1000V

Measuring range [SCCM]
0~3... 30
Output signal
Analog, RS485 (Modbus), I2C
Accuracy [± % FS] max.
±2.5
Supply voltage [VDC]
8 ~ 24

PFLOW-ELEMENT

Measuring range [SCCM]
Customized
Output signal
Customized
Accuracy [± % FS] max.
Customized
Supply voltage [VDC]
Customized

SQ-UST_L_0001-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+90°C

SQ-UST_L_0002-01

Operating medium
Flüssigkeit
Contact area
Messing
Temperature range
+130°C

SQ-UST_L_0003-01

Operating medium
Flüssigkeit
Contact area
Kunststoff
Temperature range
+55°C

SQ-UST_L_0103-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+75°C

SQ-UST_L_0104-01

Operating medium
Flüssigkeit
Contact area
Stahl
Temperature range
+75°C

SQ-UST_L_0105-01

Operating medium
Flüssigkeit
Contact area
Messing
Temperature range
+90°C

SQ-UST_G_0001-01

Operating medium
Gas
Contact area
Glas-Epoxy
Temperature range
+70°C

SQ-FM2PA61-10M

Power Supply
0,3 to 30 l/min Flow Detection < 0,3 l/min is possible
Power Supply
3,0 to 3,3 Vcc / typ. < 30 mA
Pipe
DN10; Pipe Material PA61
Operation Temperature
5 °C to 60 °C

SQ-FM2PA61-10EK

Power Supply
0,3 to 30 l/min Flow Detection < 0,3 l/min is possible
Power Supply
3,0 to 3,3 Vcc / typ. < 30 mA
Pipe
DN10; Pipe Material PA61
Operation Temperature
5 °C to 60 °C